Temperature, Pressure and Vibration Streams Joining and finding simple pattern
Join Example 1 – Let’s take example of IOT scenario.
There are three sensors for temperature, pressure and vibration.
We wish to join these streams such that for each point we get all these three values as they arrive.
And in the end we would like to notify when temp, pressure and vibration all satisfy some condition,
here when (temp > 71.1 and pressure > 11.1 and vibration > 35)
Note that, this condition is applied on the temp_pressure_vibration stream, stream which has finally all the three data points.
A schematic diagram for the stream join is provided below for clarity.
Joining of streams are happening on simple condition, i.e. where s2.point = s2.point, this is done by A schematic diagram for the stream join is provided below for clarity.
“jqry”:{“cond”:[“point”], “opid”:11, “args”:[“point”]},
note opid = 1 is for comparing attribute value and implicit default “comparison” is “equal”.
To override for other comparison (line greater than, less than equal to, etc.
We can add “cmp”:[“GT”, “LTE”] in the jqry. The implicit is “cmp”:[“EQ”]
temperature stream +==> temp_pressure stream pressure stream + ===> temp_pressure_vibration stream vibration stream
Example 1
Here we will use join_type = 1, that’s simple join, which means both streams would actively join with each other, but once joined they will not use the same event data for next joinLet’s define the sample stream first
{ "schema":"myschema", "streams":[ { "name":"temp_stream", "type":1, "swsz":81600, "inpt":[ ], "attr":[ { "name":"temp", "type":11 }, { "name":"point", "type":9 } ], "join":[ { "name":"temp_pressure_join", "type":1, "tloc":300, "iatr":[ "temp", "point" ], "rstm":"pressure_stream", "ratr":[ "pressure" ], "jqry":{ "cond":[ "point" ], "opid":11, "args":[ "point" ] }, "ostm":"temp_pressure_stream" } ] }, { "name":"pressure_stream", "type":1, "inpt":[ ], "attr":[ { "name":"pressure", "type":11 }, { "name":"point", "type":9 } ], "join":[ { "name":"temp_pressure_join", "type":1, "tloc":300, "ratr":[ "temp", "point" ], "rstm":"temp_stream", "iatr":[ "pressure" ], "jqry":{ "cond":[ "point" ], "opid":11, "args":[ "point" ] }, "ostm":"temp_pressure_stream" } ] }, { "name":"vibration_stream", "type":1, "inpt":[ ], "attr":[ { "name":"vibration", "type":9 }, { "name":"point", "type":9 } ], "join":[ { "name":"temp_pressure_vibration_join", "type":1, "tloc":300, "ratr":[ "temp", "pressure", "point" ], "rstm":"temp_pressure_stream", "iatr":[ "vibration" ], "jqry":{ "cond":[ "point" ], "opid":11, "args":[ "point" ] }, "ostm":"temp_pressure_vibration_stream" } ] }, { "name":"temp_pressure_stream", "type":3, "inpt":[ "temp_stream", "pressure_stream" ], "attr":[ { "name":"point", "type":9 }, { "name":"temp", "type":11 }, { "name":"pressure", "type":11 } ], "join":[ { "name":"temp_pressure_vibration_join", "type":1, "tloc":300, "iatr":[ "temp", "pressure", "point" ], "rstm":"vibration_stream", "ratr":[ "vibration" ], "jqry":{ "cond":[ "point" ], "opid":11, "args":[ "point" ] }, "ostm":"temp_pressure_vibration_stream" } ] }, { "name":"temp_pressure_vibration_stream", "type":3, "inpt":[ "temp_pressure_stream", "vibration_stream" ], "attr":[ { "name":"point", "type":9 }, { "name":"temp", "type":11 }, { "name":"pressure", "type":11 }, { "name":"vibration", "type":9 } ], "cepq":[ { "name":"temp_press_vib_cond", "type":6, "tloc":86400, "fqry":{ "name":"{\"query\":[{\"key\":\"temp\", \"cmp_op\":0, \"val\":71.1},{\"joinop\":0},{\"key\":\"pressure\", \"cmp_op\":0, \"val\":11.0},{\"joinop\":0},{\"key\":\"vibration\", \"cmp_op\":0, \"val\":35}]}", "type":1 }, "notf":12345 } ] } ], "notifs":[ { "notifid":12345, "name":"notif1", "msg":"users msg", "rule":"notification rule/condition", "pri":1, "mailto":[ ], "endpoints":[ "http://192.168.1.49:10102/iot" ], "schemaid":1234, "notif_streamid":4321, "notif_stream_name":"sdf", "freq":1, "tags":[ "a" ], "rel_streams":[ "s1" ] } ] }Three streams, they each measure temp, pressure and vibration for the point p. temp_stream and pressure_stream are joining with each other to send data to temp_pressure_stream. Further, vibration_stream and temp_pressure_stream are joining together to send data to temp_pressure_vibration_stream.
The join condition for all of these streams are s1.point = s2.point, i.e. join on point.
Finally, from the temp_pressure_vibration_stream notification is sent when temp greater than 71.1 AND pressure greater than 11.0 AND vibration is greater than 35.
Note that “type” in each join is set to 1, which denotes simple join
Now, let’s push some data in following order;
put [ temp_stream ] : {"temp":70.1, "point":1} put [ pressure_stream ] : {"pressure":10.2, "point":1} put [ pressure_stream ] : {"pressure":11.1, "point":1} put [ vibration_stream ] : {"vibration":30, "point":1} put [ pressure_stream ] : {"pressure":11.5, "point":1} put [ vibration_stream ] : {"vibration":40, "point":1} put [ pressure_stream ] : {"pressure":11.8, "point":1} put [ temp_stream ] : {"temp":71.1, "point":1} put [ vibration_stream ] : {"vibration":50, "point":1} put [ temp_stream ] : {"temp":71.2, "point":1} put [ vibration_stream ] : {"vibration":60, "point":1}
Now let’s scan and see data from different streams.
Here are the data in temp stream ;
{ "temp":70.10000000000001, "point":1, "_pk":1584944534256620, "_v":1 } { "temp":71.10000000000001, "point":1, "_pk":1584944534362863, "_v":1 } { "temp":71.2, "point":1, "_pk":1584944534396958, "_v":1 }Here are the data in pressure stream;
{ "pressure":10.2, "point":1, "_pk":1584944534266887, "_v":1 } { "pressure":11.1, "point":1, "_pk":1584944534280460, "_v":1 } { "pressure":11.5, "point":1, "_pk":1584944534308709, "_v":1 } { "pressure":11.8, "point":1, "_pk":1584944534332148, "_v":1 }Here are the data in vibration stream;
{ "vibration":30, "point":1, "_pk":1584944534296090, "_v":1 } { "vibration":40, "point":1, "_pk":1584944534320131, "_v":1 } { "vibration":50, "point":1, "_pk":1584944534384031, "_v":1 } { "vibration":60, "point":1, "_pk":1584944534397786, "_v":1 }Here are the data in temp_pressure stream;
{ "pressure":10.2, "_pk":1584944534266887, "temp":70.10000000000001, "point":1, "_jpk1":1584944534256620, "_v":1 } { "temp":71.10000000000001, "point":1, "_pk":1584944534362863, "pressure":11.1, "_jpk1":1584944534280460, "_v":1 } { "temp":71.2, "point":1, "_pk":1584944534396958, "pressure":11.5, "_jpk1":1584944534308709, "_v":1 }Here are the data in temp_pressure_vibration stream;
{ "vibration":30, "_pk":1584944534296090, "temp":70.10000000000001, "pressure":10.2, "point":1, "_jpk1":1584944534266887, "_v":1 } { "temp":71.10000000000001, "pressure":11.1, "point":1, "_pk":1584944534362863, "vibration":40, "_jpk1":1584944534320131, "_v":1 } { "temp":71.2, "pressure":11.5, "point":1, "_pk":1584944534396958, "vibration":50, "_jpk1":1584944534384031, "_v":1 }Finally there is notification sent out from the following joined stream;
{ "notifid":12345, "name":"notif1", "msg":"users msg", "rule":"notification rule/condition", "pri":1, "mailto":[ ], "endpoints":[ "http://192.168.1.49:10102/iot" ], "schemaid":1234, "notif_streamid":4321, "notif_stream_name":"sdf", "freq":1, "tags":[ "a" ], "rel_streams":[ "s1" ], "count":1, "dur":0, "notif_event":{ "temp":71.2, "pressure":11.5, "point":1, "_pk":1584944534396958, "vibration":50, "_jpk1":1584944534384031, "_v":1 }, "count":1, "count_this_notif":1, "dur":0 }